The DIN Power Module (DPM) family is a group of modular products for the control of lighting loads and motor loads. This document describes the following product: LQSE-4A5-230-D: 4-Zone DIN Power Module for phase control dimming of lighting loads
Features
• Can be used in HomeWorks and HomeWorks QS systems.
• Includes QS link for seamless integration of lights and controls.
• An auto-detect mode is available to detect and configure forward-phase or reverse-phase (leading-edge or trailing-edge) dimming for incandescent / halogen, electronic / magnetic low voltage and neon / cold cathode light sources.
• A locked forward-phase or reverse-phase (leadingedge or trailing-edge) mode is available.
• Controls dimmable LED loads. Refer to www.lutron.com/ledtool for compatibility with dimmable LED light sources.
• RTISS technology compensates for incoming mains voltage variations such as changes in Root Mean Square (RMS) voltage, frequency shifts (up to ± 2% change in frequency /second), harmonics and line noise.
• RTISS-TE technology allows for true instantaneous voltage compensation for incoming mains voltage variations. Only operates in reverse-phase (trailing edge) when “voltage-comp.” is enabled.
• RTISS-ICM technology is able to withstand highinrush LEDs, bulb blowouts, and direct shorts.
• Provides air gap off (when all zones are off).
• Integral protection for common temporary over-current and over-voltage conditions.
• LEDs on the module provide diagnostic information.
Power
• 220 – 240 V~ 50/60 Hz
• 10 A maximum total input current.
• Lightning strike protection meets ANSI/IEEE standard 62.31-1980. Can withstand voltage surges of up to 6000 V and current surges of up to 3000 A.
• Contact Lutron for applications where the electrical distribution system does not have a connection to earth, an IT network per IEC 60364, such as an ungrounded Delta feed.
Regulatory Approvals
• Lutron Quality Systems registered to ISO 9001.2015
• RoHS Compliant
• CE marked
• UKCA marked
• Rated for 150 W of LEDi per IEC 60669
Environment
• Relative humidity: less than 90% non-condensing.
• For indoor use only.
Output Zone Ratings
• Each zone has no minimum load requirement.
• When programmed to “auto detect” mode, the module starts in reverse-phase (trailing-edge) and if an incompatible load is detected, it will convert to forward-phase (leading-edge).
• Internal relay provides an air gap off when all zones are off.
• One load type per zone.
• Output must not be used to control general purpose receptacles.