Additional information
Brand |
---|
Brand |
---|
The HomeWorks® QS processor provides control and communication to HomeWorks® QS system components.
The Ethernet links allow communication to the HomeWorks® QS software, integration with third party systems and communication between multiple processors. HomeWorks® QS processors may be connected using either standard networking or using ad-hoc networking. All processors on a project must be connected to a single network.
The HomeWorks® QS software and all integration equipment must be connected to the same network as the processors.
The processor is powered from the QSPS-DH-1-75 or QSPS-DH-1-60 power supply. Refer to the
HomeWorks® QS software to determine link power requirements. The HomeWorks® QS processor can be installed in a HQ-LV21, L-LV21, L-LV14, or PNL-8 enclosure.
Processor Capabilities
Each HomeWorks® QS processor has 2 links that can be individually configured as one of four types:
• HomeWorks® / HomeWorks® QS Power Panels 16 interfaces / 256 zones
• HomeWorks® QS Wired Device Link 99 devices / 512 zones
• HomeWorks® QS RF Link 99 devices / 100 zones
• HomeWorks® / HomeWorks® QS Wired Dimmers 4 interfaces / 192 zones
Power; Processor (P): 24 V- 250 mA Links (L1 / L2): 24 V- 2 A per link
Typical Power Consumption; 5 W; 8 Power Draw Units (PDUs) Test conditions: Two Ethernet links connected, both device links in use
Regulatory Approvals; UL, cUL, CE, CTICK
Environment; Indoor use only. 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing
Heat Generated; 17 BTU/hr — typical (24 BTU/hr with 2 links at 2 A each output)
Cooling Method; Passive Cooling
Power Failure Memory; System data stored in non-volatile memory. Timeclock retention for
10 years
Internal Timeclock; ±1 minute per year
Miswire Protection; All terminal block inputs are over-voltage and miswire protected against wire reversals and shorts.
Low-Voltage Power Wire Type; 18 AWG (0.75 mm2)
Communications; Ethernet, RS485 (QS, RF, Power Panel)
Link Capacities;
HomeWorks® / HomeWorks® QS Power Panels 16 interfaces/256 zones
HomeWorks® QS Wired Device Link 99 devices/512 zones
HomeWorks® QS RF Link 99 devices/100 zones
HomeWorks® / HomeWorks® QS Wired Dimmers 4 interfaces/192 zones
ESD Protection; Meets or exceeds the IEC 61000-4-2 standard
Surge Protection; Meets or exceeds ANSI/IEEE C62.41 standard
Mounting Mounts; in HQ-LV21, L-LV14, L-LV21, or PNL-8 enclosure
Dimensions; With terminal blocks (as shown): 4.27 in (108 mm) x 6.0 in (152 mm)
Without terminal blocks: 4.27 in (108 mm) x 5.26 in (134 mm)
Connections; Two 5-pin removable terminal blocks* for Links 1 and 2.
One 5-pin removable terminal block* for Power Input.
Two RJ45 standard Ethernet connections.
*Each terminal will accept up to two 18 AWG (0.75 mm2) wires.