HomeWorksR QS Hybrid Repeater

Enquire
Category: Tag:

Additional information

Brand

HomeWorksR  QS Hybrid Repeaters add wireless Radio Frequency (RF) communication and extend the range of RF signals that are sent between dimmers, switches, keypads, visor control receivers, shades / draperies, and other devices. Repeaters ensure error-free communication between system components and prevent interference from neighboring systems. The first repeater connects to the HomeWorksR  QS processor to provide RF communication that extends up to 30 ft (9 m) in every direction. Up to four (4) total Hybrid Repeaters can be used per link to extend the RF range for larger system applications. Each Repeater has an RF range of 30 ft (9 m) between repeater and devices or 60 ft (18 m) between repeaters, covering a total area of approximately 2500 sq ft (232 m().

Power –

  • Hybrid Repeater: DC adapter: 9 V- 300 mA Link: 24 V- 50 mA
  • DC adapter: Input: 100-240 V~ 50/60 Hz 6.5 W Output: 9 V- 300 mA

Typical Power Consumption – Hybrid Repeater: 0.6 W Test conditions: one LED on, powered by a 9 V- adapter.

Regulatory Approvals – Hybrid Repeater: FCC, IC, COFETEL, CE, CCC, TRA, CTICK, ANATEL, IDA, SUPERTEL, SUTEL

Environment – Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only. Unit generates heat, maximum 4 BTU/hr

Low-Voltage Wire Type – Two pair – one pair 18 AWG (1.0 mm2), one pair 22 AWG to 18 AWG (0.5 mm2 to 1.0 mm2) twisted shielded – NEC® Class 2 / PELV cable. Required for connecting the first repeater to the processor and may be used to connect additional Hybrid Repeaters.

Communications – The first Hybrid Repeater communicates with the HomeWorksR QS processor on the RF wired link. Subsequent Repeaters may be wired on this link or may communicate over Radio Frequency (RF). All RF devices must be located within 30 ft (9 m) of a Repeater. All Repeaters must be within 60 ft (18 m) of another Repeater.

ESD Protection – Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2.

Surge Protection – Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits.

Power Failure – Power failure memory: should power be interrupted, the Repeater will return to its previous state when power is restored.

Mounting – Mount on a wall, ceiling, or level surface using the two #6 (M3) screws provided.